The SD70 is 72' 4" in length over the couplers and stands 15' 7.57" high over the cooling fan guards
The unit is 12' 1" wide over the snowplow
Distance between the bolsters is 48' 8"
General
Built in 1998, Order Number 976826
Weight- 385,000lbs
Maximum Curvature Per Single Unit- 27.8 °
Horsepower- 4000
Maximum Continuous Tractive Effort- 109,150lbs
Minimum Continuous Speed- 11.4mph
Maximum Speed- 70mph
Traction Motor Rating- 1230 amps
Dynamic Brake- High Capacity Extended Range
Maximum Dynamic Braking Effort- 87,000lbs
Speed At Maximum Braking Effort- 9-22.4mph
Schedule- Epic II
Automatic Brake Valve- Epic II
Independent Brake Valve- Epic II
Control Valve- Epic II
Application Valve- Epic II
Relay Valve- Epic II
Vent Valve- 2, No. 8
Safety Control- EMD ICE
Horn- Nathan K5LA-R24
Air Filters, Brake- Salem 975-075 Auxiliary- Salem 975-075
Air Dryer- Salem 505-975-100
Radio Provision- All Channel Clean Cab
Cab Heater- Electric
Speed Recorder- EMD ICE
Speed Indicator- EMD ICE
Water Cooler- Portable Cooler
Toilet System- Chemical
Snow Plow- Short Hood End
Electronic Cab Display
Spotter
Self Load Test
Emergency Cranking Receptacles
Roof Top Air Conditioner
Motorized Air Compressor
Electronic Fuel Injection- EMD EUI
Cab Signal Equipped
LSL Equipped
Allignment Control Coupler Equipped
Assembled At CR Juniata Locomotive Shop